Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +49 (71 91) 47-0

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Mounting method:
Family construction form:
No. of poles:
Electrical data | Supply
Operating voltage DC max.:
Operating voltage DC max. (UL-listed):
Current operating per contact max.:
Industrial communication
Transfer parameters:
Diagnostics
Status indication LED:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Mechanical data
Contour for corrugated hose:
Mechanical data | Material data
Material housing:
Locking material:
Mechanical data | Mounting data
Looking techniques:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Stranding (type 2):
Banding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Electrical capacity line constant (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
Packaging unit:
customs tariff number:
GTIN:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Move
RJ45 male 0° shielded with cable, Gigabit RJ45 male 0° shielded with cable, Gigabit
TPE 4x2x24AWG SF/UTP CAT5e bu UL/CSA, CM 5m
Weight: 0.353 kg
Art.No.: 7700-74118-S4W0500

Available
Move
RJ45 male 0° shielded with cable, Gigabit RJ45 male 0° shielded with cable, Gigabit
TPE 4x2x24AWG SF/UTP CAT5e bu UL/CSA, CM 7,5m
Weight: 0.523 kg
Art.No.: 7700-74118-S4W0750

Available
5 m
7,5 m
inserted
inserted
RJ45
RJ45
8
8
60 V
60 V
30 V
30 V
1,5 A
1,5 A
CAT5e
CAT5e
no
no
IP20
IP20
inserted, screwed
inserted, screwed
3
3
without
without
PUR
PUR
PA
PA
Snap-in connector
Snap-in connector
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
S4W
S4W
blue
blue
cURus
cURus
4
4
2 wires twisted
2 wires twisted
4 Stranded joints twisted
4 Stranded joints twisted
Foil
Foil
(orange-white, orange), (blue-white, blue), (brown-white, brown), (green-white, green)
(orange-white, orange), (blue-white, blue), (brown-white, brown), (green-white, green)
74,8 g/m
74,8 g/m
TPE
TPE
lead-free, CFC-free
lead-free, CFC-free
7,6 mm
7,6 mm
± 5 %
± 5 %
HDPE
HDPE
8
8
1,17 mm
1,17 mm
± 5 %
± 5 %
lead-free, CFC-free
lead-free, CFC-free
7
7
24 AWG
24 AWG
24 AWG
24 AWG
copper stranded wire, tinned
copper stranded wire, tinned
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4 A
4 A
59 Ω/km @ 20 °C
59 Ω/km @ 20 °C
3 kV @ 60 s
3 kV @ 60 s
49000 pF/km
49000 pF/km
3 kV @ 60 s
3 kV @ 60 s
-40 °C
-40 °C
80 °C
80 °C
-5 °C
-5 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
1 Mio. @ 25 °C
1 Mio. @ 25 °C
3 Mio. 25 °C
3 Mio. 25 °C
± 270 °/m
± 270 °/m
27061801
27061801
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
EC002599
EC002599
1
1
85444210
85444210
4048879679428
4048879679435
* plus VAT, plus shipping