Technical Data
Cable length:
Electrical data | Supply
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Current consumption max.:
Diagnostics
Status indication LED:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Rated surge voltage:
Device protection | Media
Flame resistance:
Mechanical data | Material data
Color housing:
Material housing:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
Cable
wire arrangement:
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
customs tariff number:
Packaging unit:
Move
Valve plug MJC 0° with cable LED Valve plug MJC 0° with cable LED
PVC 2x0.75 bk 2m
Weight: 0.113 kg
Art.No.: 7000-70021-7520200

Available
Move
Valve plug MJC 90° with cable LED Valve plug MJC 90° with cable LED
PVC 2x0.75 bk 3m
Weight: 0.157 kg
Art.No.: 7000-70321-7520300

Contact Us for Availability
2 m
3 m
10 V
10 V
30 V
30 V
10 V
10 V
30 V
30 V
4 A
4 A
12 mA
12 mA
yellow
yellow
IP65
IP65
inserted, locked
inserted, locked
0,8 kV
0,8 kV
flame retardant
flame retardant
black
black
Plastic
Plastic
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
brown, blue
752
752
black
black
-
-
1
1
2 wires twisted
2 wires twisted
brown, blue
brown, blue
50,6 g/m
50,6 g/m
PVC
PVC
80 ± 5 Shore A
80 ± 5 Shore A
lead-free, cadmium-free, CFC-free
lead-free, cadmium-free, CFC-free
5,2 mm
5,2 mm
± 5 %
± 5 %
PVC
PVC
2
2
1,8 mm
1,8 mm
± 5 %
± 5 %
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
24
24
0,2 mm
0,2 mm
0,75 mm²
0,75 mm²
Stranded copper wire, bare
Stranded copper wire, bare
Strand class 5
Strand class 5
500 V
500 V
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
12 A
12 A
26 Ω/km @ 20 °C
26 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-30 °C
-30 °C
70 °C
70 °C
-5 °C
-5 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
10 x Outer diameter
10 x Outer diameter
15 x Outer diameter
15 x Outer diameter
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879135528
4048879286220
85444290
85444290
1
1
* plus VAT, plus shipping